Back Up Next

Latest results (Japan)

Grain structure studies using Orientation Imaging Microscopy (OIM) on tempered power plant steels [4, 5]

Studies grain orientation and calculates grain boundary characteristics

Found that grains are elongated and size is rather inhomogeneous

So grain size is perhaps not a good parameter to measure

But clear relaxation of structure visible with longer tempering time